222
Chapter 6 System configuration using the Console Interface
320985-A Rev 01
describes the
System Characteristics
screen fields
Table 49
System Characteristics screen fields
Field
Description
Operation Mode
Read-only field that indicates the operation mode of the unit, for example:
•
When the unit is part of a stack configuration, the (read-only) field indicates the
unit is operational in a stack, and lists the current unit number of this switch. In
this example (see
), the current unit number is Unit 2.
•
When the unit is
not
part of a stack configuration (operating standalone), the
read-only field indicates the unit is operating as a switch. When in this operation
mode, the Size of Stack and Base Unit fields (see following description) do not
appear.
Size of Stack
This read-only field only appears when the switch is participating in a stack
configuration. This field indicates the number of units configured in the stack
configuration (1 to 8 units maximum).
Base Unit
This read-only field only appears when the switch is participating in a stack
configuration. This field indicates the unit number of the switch that is currently
operating as the base unit.
MAC Address
The MAC address of the switch or, when the switch is participating in a stack
configuration, the MAC address of the stack configuration.
Reset Count
A read-only field that indicates the number of resets since the operational firmware
was first loaded on the switch.
Default Value
1
Range
0 to 2
32
-1 (4,294,967,295)
Last Reset Type
A read-only field that indicates the last type of reset.
Default Value
Power Cycle
Range
Power Cycle, Software Download, Management Reset,
Management Factory Reset
Power Status
A read-only field that indicates the current power source (primary, RPSU, or both).
Default Value
Primary Power
Range
Primary Power, Redundant Power, Primary and Redundant
Power
Local GBIC Type
A read-only field that indicates the GBIC type that is configured in this unit. (This field
is applicable only to the Ethernet Switch 425).
sysDescr
A read-only field that specifies hardware and software versions.
sysObjectID
A read-only field that provides a unique identification of the switch, which contains
the vendor’s private enterprise number.
sysUpTime
A read-only field that shows the length of time since the last reset. Note that this field
is updated when the screen is redisplayed.
Содержание 425-24T
Страница 20: ...20 Contents 320985 A Rev 01 ...
Страница 38: ...38 Preface 320985 A Rev 01 ...
Страница 188: ...188 Chapter 4 Getting Started with Device Manager 320985 A Rev 01 Figure 64 Line graph Figure 65 Area graph ...
Страница 189: ...Chapter 4 Getting Started with Device Manager 189 System Configuration Guide Figure 66 Bar graph Figure 67 Pie graph ...
Страница 198: ...198 Chapter 4 Getting Started with Device Manager 320985 A Rev 01 ...
Страница 212: ...212 Chapter 5 Using the Web based management interface 320985 A Rev 01 ...
Страница 318: ...318 Chapter 7 System configuration using the CLI 320985 A Rev 01 ...
Страница 336: ...336 Chapter 8 Ethernet port management using the CLI 320985 A Rev 01 ...
Страница 384: ...384 Chapter 11 Administering the switch using Web based management 320985 A Rev 01 ...
Страница 404: ...404 Chapter 12 Configuring the switch using Web based management 320985 A Rev 01 ...
Страница 424: ...424 Installing an SFP Transceiver 320985 A Rev 01 ...
Страница 442: ...442 Default settings 320985 A Rev 01 ...
Страница 468: ...468 Command List 320985 A Rev 01 ...
Страница 474: ...474 Technical specifications 320985 A Rev 01 ...
Страница 488: ...488 Index 320985 A Rev 01 ...