Troubleshooting
ASDA-A3
11-28
Revision December, 2017
11
AL085 Regeneration error
Trigger condition
and causes
Condition: regeneration control error.
Cause: regenerative resistor is not operating, but the generative voltage
remains at 400V for a period of time.
Checking methods
and corrective
actions
Check the connections for the regenerative resistor, re-calculate the value
for the regenerative resistor, and reset the value of P1.052 and P1.053. If
this does not clear the alarm, please send the servo drive back to Delta.
How to clear the
alarm?
DI.ARST
AL086 Input voltage is too high
Trigger condition
and causes
Condition: when the servo drive detects no regenerative power, but other
regenerative energy (such as interference) is input to the servo drive, or
voltage input is higher than the permissible rated voltage.
Causes:
1. Other energy (such as interference) is input to the servo drive or the
input voltage is higher than the permissible rated value.
2. Malfunction of the servo drive hardware.
Checking methods
and corrective
actions
1. Use a voltmeter to measure if the input voltage from the power source
is within the permissible rated value (see the servo drive specifications).
If the voltage exceeds the rated value, please remove the interference
source.
2. If the voltmeter detects that the voltage from the main circuit is within
the permissible rated range, but the issue persists, then the servo drive
may be malfunctioning.
How to clear the
alarm?
1. Use the correct voltage source or connect the voltage regulator in
series.
AL088 Servo function overload warning
Trigger condition
and causes
Condition: too many motor control functions on the servo drive are enabled.
Cause: Servo function overload warning.
Checking methods
and corrective
actions
If using a filter, see if using this filter is necessary.
Содержание ASD-A3-0121
Страница 13: ...Revision December 2017 This page is intentionally left blank...
Страница 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Страница 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Страница 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Страница 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Страница 483: ...MODBUS Communication ASDA A3 9 16 Revision December 2017 9 This page is intentionally left blank...
Страница 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Страница 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Страница 603: ...4 Revision December 2017 This page is intentionally left blank...