Wiring ASDA-A3
3-50
Revision December, 2017
3
3.9 CN10 STO connector (Safe torque off )
This connector provides the STO function. More details are provided in the next section.
Note:
1. The STO function is supported by the A3-M only.
2. STO certification application in progress.
(1) CN10 STO connector (Female) (2) CN10 quick connector (Male)
Pin assignment:
Pin No.
Signal
Function
1
Reserved
Reserved
2
Reserved
Reserved
3
STO_A
STO input A+
4
/STO_A
STO input A-
5
STO_B
STO input B+
6
/STO_B
STO input B-
7
FDBK+
STO alarm output (+), BJT Output
Max. rating: 80 V
DC
, 0.5 A
8
FDBK-
STO alarm output (-), BJT Output
Max. rating: 80 V
DC
, 0.5 A
If you use the STO function, you can plug in the STO
connector that comes with the servo drive. The wiring has
been done as shown in the figure on the right. If this
connector has been disassembled, refer to section 3.9
STO Function (Safe Torque Off) for wiring information.
Содержание ASD-A3-0121
Страница 13: ...Revision December 2017 This page is intentionally left blank...
Страница 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Страница 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Страница 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Страница 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Страница 483: ...MODBUS Communication ASDA A3 9 16 Revision December 2017 9 This page is intentionally left blank...
Страница 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Страница 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Страница 603: ...4 Revision December 2017 This page is intentionally left blank...