Troubleshooting
ASDA-A3
11-26
Revision December, 2017
11
AL07B Encoder memory busy
Trigger condition
and causes
Encoder memory is busy.
Checking methods
and corrective
actions
1. Check if the motor is well grounded; make sure the power cable is
grounded to the heat sink of the servo drive.
2. Make sure the encoder cable is separated from the power supply or any
high-current cables to avoid interference.
3. Use shielded cable for the encoder and pull out the shielded mesh and
ground it.
4. Check the motor speed and make sure it is within the rated range.
If the issue persists, please send your servo drive back to the distributor or
contact Delta.
How to clear the
alarm?
Cycle power on the servo drive.
AL07C Command to clear the absolute position is issued when the motor speed is
over 200 rpm
Trigger condition
and causes
The command to clear the absolute position is issued when the motor
speed is over 200 rpm.
Checking methods
and corrective
actions
Check if a command to clear the absolute position is issued while motor
speed is over 200 rpm. If so, follow the procedure for clearing the absolute
position to clear this alarm.
Do not issue a command to clear the absolute position when the motor
speed is over 200 rpm.
How to clear the
alarm?
Cycle power on the servo drive.
AL07D Servo drive power is cycled before AL07C is cleared
Trigger condition
and causes
AL07C occurs and is not cleared before the power is cycled on the servo
drive, and the motor stops operating.
Checking methods
and corrective
actions
Use DI.ARST to clear the alarm. Once this alarm is cleared, AL07C occurs.
Please follow the checking and troubleshoot methods to clear that alarm.
How to clear the
alarm?
Cycle power on the servo drive.
Содержание ASD-A3-0121
Страница 13: ...Revision December 2017 This page is intentionally left blank...
Страница 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Страница 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Страница 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Страница 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Страница 483: ...MODBUS Communication ASDA A3 9 16 Revision December 2017 9 This page is intentionally left blank...
Страница 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Страница 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Страница 603: ...4 Revision December 2017 This page is intentionally left blank...