Motion Control
ASDA-A3
7-60
Revision December, 2017
7
With two channels available, you can use the panel, communication, or ASDA-Soft to read data
from, or write data to, the data array. You can set channel 1 with P5.011, P5.012, and P5.013.
P5.011 specifies the address for reading and writing the data array. P5.012 and P5.013 define
the windows for reading and writing. You can use both to read and write, but the behaviors after
reading and writing differ. Please refer to Table 7.2.1.1. You can set channel 2 by P5.011 and
P5.100–103. P5.011 sets the address for reading and writing the data array. P5.100 can read
data from, or write data to, the data array address following the address set by P5.011. P5.012
and P5.103 work the same way. If the address number has reached the maximum (799), then
the address remains at 799 instead increasing. You can find more details in Table 7.2.1.2.
Table 7.2.1.1 Channel 1
–
reading / writing the data array
Parameter
Description
P5.011
Address for
reading / writing
Specify the address for reading from or writing to the data array
Window for
reading / writing
by
Behavior after reading
Behavior after writing
P5.012
Window #1 for
reading / writing
Panel
Value of P5.011 does not add
1
Value of P5.011 adds 1
Communication /
ASDA-Soft
Value of P5.011 adds 1
Value of P5.011 adds 1
P5.013
Window #2 for
reading / writing
Panel
Value of P5.011 adds 1
Cannot be written with the
drive panel
Communication /
ASDA-Soft
Value of P5.011 adds 1
Value of P5.011 adds 1
Example: when using the drive panel or communication for reading from or writing to the
data array, input values to the data array address in sequence as follows: Data array #11 =
100, Data array #12 = 200, Data array #13 = 300. Then the data is read in sequence.
1.
Read / write via panel:
Write
P5.011 = 11
P5.013
Not writable via
panel
P5.011 (writing address)
adds 1
P5.011 = 12
Write
P5.012 = 100
Write
P5.012 = 200
Read
P5.012 = 100
Read
P5.012 = 200
P5.011 (writing address)
adds 1P5.011 = 13
Write
P5.012 = 300
Read
P5.013 = 100
P5.011 (reading
address) remains
P5.011 = 11
Write
P5.011 = 12
P5.011 (reading
address) remains
P5.011 = 12
Read
P5.012 = 300
Write
P5.011 = 13
P5.011 (reading
address) adds 1
P5.011 = 12
Read
P5.013 = 200
P5.011 (reading
address) adds 1
P5.011 = 1
Write to data array
Read from data array
Set the address
for writing the
first data
Write 100 to
Data array#11
Write 200 to
Data array#12
Write 300 to
Data array#13
Write
P5.011 = 11
Set the address
for reading the
first data
Read
Data array#11
Read
Data array#12
Read
P5.013 = 300
Read
Data array#13
Содержание ASD-A3-0121
Страница 13: ...Revision December 2017 This page is intentionally left blank...
Страница 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Страница 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Страница 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Страница 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Страница 483: ...MODBUS Communication ASDA A3 9 16 Revision December 2017 9 This page is intentionally left blank...
Страница 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Страница 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Страница 603: ...4 Revision December 2017 This page is intentionally left blank...