ASDA-A3
Troubleshooting
Revision December, 2017
11-21
11
AL060 Absolute position is lost
Trigger condition
and causes
Condition: losing number of revolutions because of low battery voltage or
loss of the power.
Causes:
1. Voltage level of the battery is too low.
2. The battery is replaced when the main power of the servo drive is off.
3. The battery is not installed when the absolute function is enabled.
4. Poor connection or disconnection of the battery power circuit.
Checking methods
and corrective
actions
1. Check if the battery voltage is below 2.8V; execute homing after
changing the battery. Please refer to Chapter 10 Absolute servo system
for more details about initializing the absolute coordinate system.
2. Do not change or remove the battery when the ASDA-A3 servo drive’s
main power is off. To execute homing again, please refer to Chapter 10
for absolute coordinate initialization.
3. Please follow the instructions below:
(A) Install the battery.
(B) Check the connection between the battery power source and the
servo drive.
(C) Check the encoder wiring.
4. Connect or correct the wiring so that the battery power is supplied to
the encoder and then execute homing again.
(A) Check the encoder wiring.
(B) Check the connection between the battery box and servo drive.
How to clear the
alarm?
Cycle power on the servo drive.
AL061 Encoder undervoltage
Trigger condition
and causes
Condition: voltage level of the absolute encoder battery is lower than the
allowable value (3.1V).
Cause: voltage level of the battery is too low.
Checking methods
and corrective
actions
1. Check the panel to see if the battery voltage is less than 3.1V.
2. Measure the battery voltage and see if it is less than 3.1V.
If the voltage is too low, replace the battery when the main power is on.
How to clear the
alarm?
The alarm is cleared automatically.
Содержание ASD-A3-0121
Страница 13: ...Revision December 2017 This page is intentionally left blank...
Страница 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Страница 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Страница 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Страница 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Страница 483: ...MODBUS Communication ASDA A3 9 16 Revision December 2017 9 This page is intentionally left blank...
Страница 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Страница 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Страница 603: ...4 Revision December 2017 This page is intentionally left blank...