Troubleshooting
ASDA-A3
11-18
Revision December, 2017
11
cause for the alarm. If the issue persists, please send your servo drive
back to the distributor or contact Delta.
(A) Make sure the servo motor is properly grounded and connect the
UVW connector (color green) to the servo drive heat sink.
(B) Make sure the encoder cable is separated from the power supply or
any high-current cables to avoid interference.
(C) Use shielded cable for the encoder. If issue persists, please send
your servo drive back to the distributor or contact Delta.
How to clear the
alarm?
Cycle power on the servo drive.
AL029 Gray code error
Trigger condition
and causes
Absolute position error.
Checking methods
and corrective
actions
Cycle the power to the servo drive to operate the motor. Then check if the
alarm occurs again. If the issue persists, please replace the encoder.
How to clear the
alarm?
Re-power on the servo drive.
AL030 Motor crash error
Trigger condition
and causes
Condition: when the motor hits the device, the torque reaches the value of
P1.057 and lasts for the time set by P1.058.
Causes:
1. Check if the function of motor crash protection (P1.057) is enabled. If
so, please set P1.057 to 0.
2. Check if the value of P1.057 is set too low and the time set by P1.058 is
too short. Please set P1.057 according to the actual torque. Incorrect
values might inadvertently trigger the signal or lose the protection
function.
Checking methods
and corrective
actions
Cycle power on the servo drive to operate the motor and check if the alarm
occurs again. If the issue persists, please replace the encoder.
How to clear the
alarm?
DI.ARST
AL031 Motor power cable incorrect wiring or disconnection
Trigger condition
and causes
Condition: incorrect wiring or disconnection of the power cable U, V, W, and
GND.
Causes:
Incorrect wiring or disconnection of motor power cable U, V, W. The switch
for cut-off detection is set by P2.065 Bit 9, which default is set to disable.
Содержание ASD-A3-0121
Страница 13: ...Revision December 2017 This page is intentionally left blank...
Страница 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Страница 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Страница 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Страница 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Страница 483: ...MODBUS Communication ASDA A3 9 16 Revision December 2017 9 This page is intentionally left blank...
Страница 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Страница 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Страница 603: ...4 Revision December 2017 This page is intentionally left blank...