Wiring ASDA-A3
3-30
Revision December, 2017
3
3.3.5 Wiring diagrams (CN1)
The valid voltage for the analog speed command and the analog torque command is between
-10 V and +10 V. You can set the command value that corresponds to the voltage range with the
relevant parameters.
C1: input for speed/torque (force) analog command
GND
Approx. 12 k
Ω
SG
42 V-REF
13
Controller
(18 T-REF)
10 k
Ω
1.2 k
Ω
10V
_+
Servo Drive
Note: this is not supported by the A3-F.
C2: output for analog monitoring command (MON1 and MON2)
10 V
full-scale
SG
13
Servo Drive
24 k
Ω
GND
MON1 16
(MON2 15)
8 k
Ω
Controller
Max. ouput:
±10 V, 1 mA
Note:
1.
Please refer to parameter P2.112 [Bit 0] for the maximum voltage for analog output. 8 V or 10 V are
suggested.
2.
This is not supported by the A3-F.
Содержание ASD-A3-0121
Страница 13: ...Revision December 2017 This page is intentionally left blank...
Страница 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Страница 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Страница 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Страница 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Страница 483: ...MODBUS Communication ASDA A3 9 16 Revision December 2017 9 This page is intentionally left blank...
Страница 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Страница 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Страница 603: ...4 Revision December 2017 This page is intentionally left blank...