ASDA-A3 Parameters
Revision December, 2017
8-207
8
Code
Variable name /
property
Description
008 (08h)
Speed command
(analog)
B
D2
Dec
Speed command from the analog channel. Unit: 0.01 Volt.
009 (09h)
Speed command
(integrated) B
Integrated Speed command. Unit: 1 rpm.
Source includes analog, register, or position loop.
010 (0Ah)
Torque command
(analog)
B
D2
Dec
Torque command from the analog channel. Unit: 0.01 Volt.
011 (0Bh)
Torque command
(integrated) B
Integrated Torque command. Unit: percentage (%).
Source includes analog, register, or speed loop.
012 (0Ch)
Average load rate B
Average load rate from the drive. Unit: percentage (%).
013 (0Dh)
Peak load rate B
Maximum load rate from the drive. Unit: percentage (%).
014 (0Eh)
DC Bus voltage B
Rectified capacitor voltage. Unit: Volt.
015 (0Fh)
Load inertia ratio
B
D1
Dec
Ratio of the load inertia to the motor inertia. Unit: 0.1 times.
016 (10h)
IGBT temperature B
Temperature of IGBT. Unit: °
C
.
017 (11h)
Resonance frequency
B
Dec
Resonance frequency of the system consists of two groups of
frequencies: F1 and F2
When monitoring from the panel, press the SHF key to switch
between F1 and F2:
F2 displays zero decimal places, F1 displays 1 decimal place.
When reading by communication (mapping parameter):
Low word displays frequency F2.
High word displays frequency F1.
018 (12h)
Z phase offset
B
Dec
Offset value between motor position and Z phase,
range: -5000 to +5000.
Where it overlaps with Z phase, the value is 0; the greater the
value, the greater the offset.
019 (13h)
Mapping parameter
content #1
B
Returns the value of P0.025 which is mapped by P0.035.
020 (14h)
Mapping parameter
content #2
B
Returns the value of P0.026 which is mapped by P0.036.
021 (15h)
Mapping parameter
content #3
B
Returns the value of P0.027 which is mapped by P0.037.
022 (16h)
Mapping parameter
content #4
B
Returns the value of P0.028 which is mapped by P0.038.
023 (17h)
Mapping monitoring
variable #1
B
Returns the value of P0.009 which is mapped by P0.017.
024 (18h)
Mapping monitoring
variable #2
B
Returns the value of P0.020 which is mapped by P0.018.
025 (19h)
Mapping monitoring
variable #3
B
Returns the value of P0.011 which is mapped by P0.019.
026 (1Ah)
Mapping monitoring
variable #4
B
Returns the value of P0.012 which is mapped by P0.020.
028 (1Ch)
Alarm code
Alarm code in DMCNET mode (applicable to A3-F).
029 (1Dh)
Auxiliary encoder
feedback (PUU)
Position feedback from the auxiliary encoder (CN5)
(applicable to A3-F).
030 (1Eh)
Auxiliary encoder
position deviation
(PUU)
Position deviation between the position feedback and the
command from the auxiliary encoder (CN5) (applicable to
A3-F).
Содержание ASD-A3-0121
Страница 13: ...Revision December 2017 This page is intentionally left blank...
Страница 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Страница 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Страница 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Страница 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Страница 483: ...MODBUS Communication ASDA A3 9 16 Revision December 2017 9 This page is intentionally left blank...
Страница 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Страница 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Страница 603: ...4 Revision December 2017 This page is intentionally left blank...