Troubleshooting
ASDA-A3
11-16
Revision December, 2017
11
How to clear the
alarm?
DI.ARST
AL024 Encoder initial magnetic field error
Trigger condition
and causes
Condition: the magnetic field of the encoder U, V, W signal is in error.
Cause: the initial magnetic field of the encoder is in error (Signal U, V, W of
the encoder magnetic field is in error.)
Checking methods
and corrective
actions
1. Make sure the servo motor is properly grounded and connect the UVW
connector (color green) to the heat sink of the servo drive.
2. Make sure the encoder cable is separated from the power supply or any
high-current cables to avoid interference.
3. Use shielded cable for the encoder.
If the issue persists, please send your servo drive back to the distributor or
contact Delta.
How to clear the
alarm?
Re-power on the servo drive.
AL025 Encoder internal error
Trigger condition
and causes
Condition: internal memory and counter of the encoder are in error.
Causes:
1. Internal encoder error (internal memory and counter are in error).
2. When applying power, the motor rotates because of inertia of the
machinery or other causes.
Checking
methods and
corrective actions
1. (A) Make sure the servo motor is properly grounded and connect the
UVW connector (color green) to the A3 servo drive heat sink.
(B) Make sure the encoder cable is separated from the power supply or
any high-current cables to avoid interference.
(C) Use shielded cable for the encoder.
2. Make sure the motor shaft does not move when power is turned on.
How to clear the
alarm?
Cycle the power to the servo drive.
AL026 Encoder unreliable internal data
Trigger condition
and causes
Condition: internal data error occurs three consecutive times.
Causes:
1. External interference.
2. Malfunction of encoder hardware.
Содержание ASD-A3-0121
Страница 13: ...Revision December 2017 This page is intentionally left blank...
Страница 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Страница 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Страница 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Страница 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Страница 483: ...MODBUS Communication ASDA A3 9 16 Revision December 2017 9 This page is intentionally left blank...
Страница 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Страница 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Страница 603: ...4 Revision December 2017 This page is intentionally left blank...