User Manual
ED12DSS Shutter Driver
14-0045 Version 2.10 2020
1.800.828.6972
Страница 1: ...User Manual ED12DSS Shutter Driver 14 0045 Version 2 10 2020 1 800 828 6972...
Страница 2: ...discontinue or change specifications or designs at any time without incurring any obligation Revision Table Version 2 10 2020 6 25 20 STP Updated Warranty to current version Updated Drawing 16 0618 F...
Страница 3: ...teed for 25 000 000 operations or one year One operation is considered one opening and one closure of the shutter DSS and ES Series shutters excluding the DSS35B must be operated with the ED12DSS or V...
Страница 4: ...autions 6 Safety Terms and Symbols 7 PREFACE 8 GETTING STARTED 9 Features 9 Introduction 10 Start Up 11 Initial Operation and Testing 12 Fuse Replacement 15 Dimensions 16 Maintenance 17 Inspection 17...
Страница 5: ...ED12DSS User Manual 5 List of Figures Figure 1 ED12DSS Connection I O Layout 13 Figure 2 ED12DSS Control Diagrams 14 Figure 3 ED12DSS Dimensions 16...
Страница 6: ...rical shock the grounding connector must be connected to earth ground Before making connections to the input or output terminals of the product ensure that the product is properly grounded Use Proper...
Страница 7: ...terms appear in this manual CAUTION Warning statements identify conditions or practices that could result in injury or loss of life Caution statements identify conditions or practices that could resul...
Страница 8: ...er details to the operational features of the driver Specifications are described for all input output controls as well as operational features of the ED12DSS Index contains a full index What follows...
Страница 9: ...pecific DSS NS series shutters via 4 position piano switch Internal fuse protection for SHUTTER OUTPUT Operates on 12 to 24 VDC at 1 5 A Power input to controller via 2 wire input harness ED IOP Input...
Страница 10: ...ially if the shutter is in an area with limited air flow This heat can cause premature failure Please contact the factory for specific information concerning shutter modifications and or drive modific...
Страница 11: ...ect the Red wire of the ED IOP harness to the side of a 12 VDC to 24 VDC 1 5A power supply 5 Connect the Black wire of the harness to the return side of the power supply 6 Connect the 5 pin female con...
Страница 12: ...tact closure follow this procedure 1 Connect a wire to pin 5 of the ED IOP harness this is the 5 VDC output 2 Switch the 5 VDC output voltage to the BNC input The shutter will open and remain open for...
Страница 13: ...ED12DSS User Manual 13 Figure 1 ED12DSS Connection I O Layout2...
Страница 14: ...ED12DSS User Manual 14 Figure 3 ED12DSS Control Diagrams...
Страница 15: ...S PCB This fuse is non replaceable 2 F2 is an SMT user replaceable fuse rated for 0 75 A 125 V time lag 3 This fuse can be removed and replaced in the field Fuses can be procured from the manufacturer...
Страница 16: ...ED12DSS User Manual 16 Dimensions The overall dimensions of the ED12DSS driver board are shown below in Figure 3 Figure 4 ED12DSS Dimensions...
Страница 17: ...calibration Failure to do this may damage the unit s circuitry and or functionality and will void the factory warranty Inspection Inspect the ED12DSS for damage wear and missing parts If the unit app...
Страница 18: ...ter s maximum rate Pulse Voltage 10 7 VDC Power Supply 12 to 24 VDC regulated 2 1 5 A minimum User Supplied External Input Characteristics Name Description TRIGGER INPUT P1 Trigger Input P1 Pin 4 Grou...
Страница 19: ...ng and or control circuits Internal fuse protected SHUTTER OUTPUT JST 2 pin connector P2 P2 Pin 1 P2 Pin 2 Shutter drive signal H Switch output Factory adjusted to 10 7 VDC This circuit provides a dri...
Страница 20: ...position 1 1 0 N A 20msec 0 0 1 N A 25msec 1 0 1 N A 30msec 0 1 1 N A 35msec 1 1 1 N A 40msec Recommended Pulse Width Settings See S1 Chart DSS10B 10 msec DSS20B 25 msec DSS25B 35 msec NS15B 10 msec...
Страница 21: ...ure time 12 EXTERNAL INPUT CHARACTERISTICS 18 EXTERNAL OUTPUT CHARACTERISTICS 19 F2 15 17 20 falling edge 12 FEATURES 9 fuse 6 10 15 19 20 FUSE REPLACEMENT 15 Fuse Requirements 20 Getting Started 8 Gr...
Страница 22: ...signal 19 SHUTTER OUTPUT 9 19 Size 9 SMT 15 20 Specifications 8 18 Suspected Failures 6 switch contact closure 9 12 Testing 12 trigger input 9 11 18 trigger signal input 9 TTL 9 11 12 18 Tyco 9 Tyco A...