Electronic Expansion Valve Coil Abnormality
Error Code
A9
Applicable
Models
Indoor units except FXFQ models
Method of Error
Detection
Check coil condition of electronic expansion valve by using micro-computer.
Error Decision
Conditions
Pin input for electronic expansion valve coil is abnormal when initializing micro-computer.
Supposed
Causes
Defective drive of electronic expansion valve
Defective of indoor unit PCB
Defective relay cables
Troubleshooting
Caution
Be sure to turn off the power switch before connecting or disconnecting connectors, or parts may be damaged.
YES
NO
NO
NO
YES
Shut the power supply OFF after
connection and then restart.
Replace the coil of electronic
expansion valve.
Replace the relay cables.
When restarting the operation
after shutting the power supply
OFF does not work, replace the
indoor unit PCB.
Electronic
expansion valve is
connected to X7A
of indoor unit PCB.
Coil check (
∗
1)
of electronic
expansion valve
drive indicates
normal.
Relay cables short
circuit or
disconnected.
∗
1. How to check the coil of electronic expansion valve drive
Remove the connector for electronic expansion valve (X7A) from PCB. Measure the resistance value
between pins and check the continuity to judge the condition.
White (1)
Red (5)
Orange (3)
φ
1
φ
3
M
φ
2
φ
4
Yellow
(2)
Brown
(6)
Blue
(4)
1) White
2) Yellow
3) Orange
4) Blue
5) Red
6) Brown
YES
The normal products will show the following conditions:
(1) No continuity between (1) and (2)
(2) Resistance value between (1) and (3) is approx. 300
Ω
(3) Resistance value between (1) and (5) is approx. 150
Ω
(4) Resistance value between (2) and (4) is approx. 300
Ω
(5) Resistance value between (2) and (6) is approx. 150
Ω