Field Setting
SiBE811001EB
123
CONVENI-PACK
These numbers represent the number of times to press the BS2 button to select each setting.
No.
Display of setting items
Display of setting conditions
Setting item
H1P H2P H3P H4P H5P H6P H7P
61
Heating capacity _ suction air
temperature correction 4
(fine-tuning of minimum value of
set temperature and absorption
temperature degree difference)
Purpose)
It uses it to adjust improvement/
down of the heating capacity.
Refer to details to another page.
k
k
k
k
k
h
k
62
Heating capacity _ suction air
temperature correction 5
(fine-tuning of maximum value of
set temperature and absorption
temperature degree difference)
Purpose)
It uses it to adjust improvement/
down of the heating capacity.
Refer to details to another page.
k
k
k
k
k
k
h
63
Heating capacity _ suction air
temperature correction 6
(fine-tuning of maximum value of
set temperature and absorption
temperature degree difference)
Purpose)
It uses it to adjust improvement/
down of the heating capacity.
Refer to details to another page.
k
k
k
k
k
k
k
Heating capacity _ suction
air temperature correction 4 H1P H2P H3P H4P H5P H6P H7P
Set 0
(factory setting)
4°C
k
h
h
h
h
h
h
Set 1
5°C
k
h
h
h
h
h
k
Set 2
6°C
k
h
h
h
h
k
h
Set 3
7°C
k
h
h
h
h
k
k
Set 4
8°C
k
h
h
h
k
h
h
Set 5
9°C
k
h
h
h
k
h
k
Set 6
10°C
k
h
h
h
k
k
h
Set 7
11°C
k
h
h
h
k
k
k
Set 8
12°C
k
h
h
k
h
h
h
Set 9
13°C
k
h
h
k
h
h
k
Set 10
14°C
k
h
h
k
h
k
h
Set 11
15°C
k
h
h
k
h
k
k
Set 12
16°C
k
h
h
k
k
h
h
Set 13
1°C
k
h
h
k
k
h
k
Set 14
2°C
k
h
h
k
k
k
h
Set 15
3°C
k
h
h
k
k
k
k
Heating capacity _ suction
air temperature correction 5 H1P H2P H3P H4P H5P H6P H7P
Set 0
(factory setting)
5°C
k
h
h
h
h
h
h
Set 1
6°C
k
h
h
h
h
h
k
Set 2
7°C
k
h
h
h
h
k
h
Set 3
8°C
k
h
h
h
h
k
k
Set 4
9°C
k
h
h
h
k
h
h
Set 5
10°C
k
h
h
h
k
h
k
Set 6
11°C
k
h
h
h
k
k
h
Set 7
12°C
k
h
h
h
k
k
k
Set 8
13°C
k
h
h
k
h
h
h
Set 9
14°C
k
h
h
k
h
h
k
Set 10
15°C
k
h
h
k
h
k
h
Set 11
16°C
k
h
h
k
h
k
k
Set 12
1°C
k
h
h
k
k
h
h
Set 13
2°C
k
h
h
k
k
h
k
Set 14
3°C
k
h
h
k
k
k
h
Set 15
4°C
k
h
h
k
k
k
k
Heating capacity _ suction
air temperature correction 6 H1P H2P H3P H4P H5P H6P H7P
Set 0
(factory setting)
8°C
k
h
h
h
h
h
h
Set 1
9°C
k
h
h
h
h
h
k
Set 2
10°C
k
h
h
h
h
k
h
Set 3
11°C
k
h
h
h
h
k
k
Set 4
12°C
k
h
h
h
k
h
h
Set 5
13°C
k
h
h
h
k
h
k
Set 6
14°C
k
h
h
h
k
k
h
Set 7
15°C
k
h
h
h
k
k
k
Set 8
16°C
k
h
h
k
h
h
h
Set 9
1°C
k
h
h
k
h
h
k
Set 10
2°C
k
h
h
k
h
k
h
Set 11
3°C
k
h
h
k
h
k
k
Set 12
4°C
k
h
h
k
k
h
h
Set 13
5°C
k
h
h
k
k
h
k
Set 14
6°C
k
h
h
k
k
k
h
Set 15
7°C
k
h
h
k
k
k
k