Field Setting
SiBE811001EB
117
CONVENI-PACK
These numbers represent the number of times to press the BS2 button to select each setting.
No.
Display of setting items
Display of setting conditions
Setting item
H1P H2P H3P H4P H5P H6P H7P
15
Setting for outdoor evaporating mode
prohibit
Purpose)
This setting saves energy by disabling
outdoor evaporating mode when heating
is set to a low temperature. (It is used in
conjunction with functions such as the
scheduler on the ST controller and is
intended for stores and other sites that do
not operate 24 hours. The correction
value for the temperature setting at which
this switch becomes active is set by 2-17.)
k
h
h
k
k
k
k
17
Correction value for remote control
settings when the outdoor
evaporating mode is prohibited
(The factory setting for the remote
control temperature when this switch
is enabled is 16°C.)
k
h
k
h
h
h
k
21
Tax1, Tay1, Tax2, and Tay2 can be
set in setting Page
(Use it with Set2-5. )
Refer to details to another page.
k
h
k
h
k
h
k
The mode of operation: Only the cooling mode and refrigeration :
at 100% H/R and Partial H/R. (5~35,64,65,70,74,75,80)
The mode of operation: At the H/P mode (40~59)
29
Target condensing temperature
selection by remote control setting
Purpose)
•The condensing temperature can be
changed during heating to save
energy or to raise the blow out
temperature.
Factory setting: +1 correction to
remote control temperature setting
of +20°C
For details, refer to the functional
description.
k
h
k
k
k
h
k
32
Target condensing temperature
setting by the outdoor air temperature
Purpose)
• The condensing temperature can be
changed during heating to save
energy particularly when the
outdoor air temperature is high.
Factory setting: Condensing
temperature 45°C when outdoor air
temperature is 20°C or more.
For details, refer to the functional
description.
k
k
h
h
h
h
h
38
Temperature difference between the
suction air temperature and the set
temperature when the outdoor
evaporating mode is prohibited
Purpose)
• When outdoor evaporating mode is
prohibited, this setting will prevent
from activating outdoor evaporating
mode even if the suction air
temperature drops below the set
temperature.
Factory setting: 6°C difference
between set temperature and
suction air temperature.
For details, refer to the functional
description.
k
k
h
h
k
k
h
40
Outdoor unit fan high static pressure
setting (standard/high static pressure)
k
k
h
k
h
h
h
58
Wetness detection time setting
* Common to "F4" and "F5"
k
k
k
k
h
k
h
H1P H2P H3P H4P H5P H6P H7P
Released outdoor evaporating
mode prohibit (Factory setting)
k
h
h
h
h
h
k
Outdoor evaporating mode
prohibit setting
k
h
h
h
h
k
h
Correction set 1
H1P H2P H3P H4P H5P H6P H7P
0°C (Factory setting)
k
h
h
h
h
h
k
+1°C
k
h
h
h
h
k
h
+2°C
k
h
h
h
k
h
h
+3°C
k
h
h
k
h
h
h
Tax1
Tay1
Tax2
Tay2
H1P H2P H3P H4P H5P H6P H7P
26°C
28°C
31°C
33°C
k
h
h
h
h
h
k
20°C
22°C
26°C
28°C
k
h
h
h
h
k
h
27°C
29°C
32°C
34°C
k
h
h
h
k
h
h
Tax1
Tay1
Tax2
Tay2
H1P H2P H3P H4P H5P H6P H7P
0°C
2°C
5°C
7°C
k
h
h
h
h
h
k
-5°C
-3°C
0°C
2°C
k
h
h
h
h
k
h
-10°C
-8°C
-5°C
-3°C
k
h
h
h
k
h
h
Target Te1
H1P H2P H3P H4P H5P H6P H7P
0°C (Factory setting)
k
h
h
h
h
h
k
+2°C
k
h
h
h
h
k
h
+1°C
k
h
h
h
k
h
h
-1°C
k
h
h
k
h
h
h
-2°C
k
h
k
h
h
h
h
-3°C
k
k
h
h
h
h
h
Target Te2
H1P H2P H3P H4P H5P H6P H7P
45°C (Factory setting)
k
h
h
h
h
h
k
42°C
k
h
h
h
h
k
h
40°C
k
h
h
h
k
h
h
38°C
k
h
h
k
h
h
h
36°C
k
h
k
h
h
h
h
Correction Set 2
H1P H2P H3P H4P H5P H6P H7P
0°C (Factory setting)
k
h
h
h
h
h
k
3°C
k
h
h
h
h
k
h
6°C
k
h
h
h
k
h
h
50°C
k
h
h
k
h
h
h
H1P H2P H3P H4P H5P H6P H7P
Standard setting
(factory setting)
k
h
h
h
h
h
k
High static pressure setting
k
h
h
h
h
k
h
H1P H2P H3P H4P H5P H6P H7P
6 hours (factory setting)
k
h
h
h
h
h
k
12 hours
k
h
h
h
h
k
h
No detection
k
h
h
h
k
h
h