![ABB Relion REC615 Скачать руководство пользователя страница 235](http://html.mh-extra.com/html/abb/relion-rec615/relion-rec615_technical-manual_3045253235.webp)
Characteristic
Value
I
Fault
= 10 × set
Start
value
PHHPTOC and
(F)PHLPTOC:
I
Fault
= 2 × set
Start val-
ue
23 ms
26 ms
29 ms
Reset time
Typically 40 ms
Reset ratio
Typically 0.96
Retardation time
<30 ms
Operate time accuracy in definite time mode
±1.0% of the set value or ±20 ms
Operate time accuracy in inverse time mode
±5.0% of the theoretical value or ±20 ms
3
±5.0% of the theoretical value or ±40 ms
3
4
Suppression of harmonics
RMS: No suppression
DFT: -50 dB at f = n × f
n
, where n = 2, 3, 4, 5,…
Peak-to-Peak: No suppression
P-to-P+backup: No suppression
4.1.1.12
Technical revision history
Table 253: PHIPTOC Technical revision history
Technical revision
Change
B
Minimum and default values changed to 40
ms for the
Operate delay
time setting
C
Minimum and default values changed to 20
ms for the
Operate delay
time setting
Minimum value changed to 1.00 x I
n
for the
Start value
setting
D
Internal improvement
E
Internal improvement
Table 254: PHHPTOC Technical revision history
Technical revision
Change
C
Measurement mode
"P-to-P + backup" re-
placed with "Peak-to-Peak"
D
Step value changed from 0.05 to 0.01 for the
Time multiplier
setting
Table continues on the next page
3
Maximum Start value = 2.5 × I
n
,
Start value multiples in range of 1.5...20
4
Valid for FPHLPTOC
1MRS758755 C
Protection functions
REC615 & RER615
Technical Manual
235