9-11
Power On Start select
Group
Code Parameter Name
Setting Range
Initial
Unit
Drive group
drv
[Drive mode]
1, 2
0 ~ 3
1
Function group 2
H20
[Power On Start select] 1
0 ~ 1
0
Set H20 to 1.
When AC input power is applied to the inverter with drv set to 1 or 2 {Run via control
terminal and one of them ON), motor starts acceleration.
This parameter is inactive when
drv
is set to 0 {Run via keypad} or 3 {RS485
communication}.
CAUTION
Particular attention must be directed to this function due to potential hazard as motor starts to
run suddenly upon applying AC input power.
Run
command
Frequency
Input voltage
When H20 is 0
When H20 is 1
Restart after fault reset
Group
Code Parameter Name
Setting Range Initial
Unit
Drive group
drv
[Drive mode]
1, 2
0 ~ 3
1
Function group 2
H21 [Restart after fault reset
selection]
1
0 ~ 1
0
Set H21 to 1.
Motor starts acceleration if
drv
is set to 1 or 2 and the selected terminal is ON when a fault
is cleared.
This parameter is inactive when
drv
is set to 0 {Run via keypad} or 3 {RS485
communication}.
CAUTION
Particular attention must be directed to this function due to potential hazard as motor starts to
run suddenly after the fault is cleared.
Summary of Contents for Sinus M
Page 10: ......
Page 15: ...1 5 Notes...
Page 16: ......
Page 50: ...6 4 Notes...
Page 78: ...8 4 Notes...
Page 114: ...10 14 Normal PID block diagram H54 0...
Page 115: ...10 15 Process PID block diagram H54 1...
Page 150: ...10 50 Notes...
Page 174: ......
Page 192: ...13 18 Notes...
Page 204: ......
Page 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...