11-14
11.6 Output terminal select at keypad-inverter communication error
Group
Display
Parameter Name
Setting
Range Default Unit
I/O group
I57
[Output terminal select
when communication
error with keypad]
-
0 ~ 3
0
Select relay output or open collector output when keypad-inverter communication fails.
Keypad and inverter CPU communication is made by serial communication.
When communication error occurs for a certain time,
will be displayed
and error signal can be output to MO or relay.
Output relay
Output terminal
Bit 1
Bit 0
0
-
-
1
-
2
-
3
0: Not used
1: Signal output to MO
2: Signal output to 30A, 30B contacts
3: Signal output to MO, 30A, 30B