9-16
Note that setting Frequency Ref. for Accel/decel (H70) is set to Max Freq and target freq is set below
Max freq. the shape of S-curve may be distorted.
Accel time for S-curve setting
2
18
2
17
H
ACC
H
ACC
ACC
×
+
×
+
=
Decel time for S-curve setting
2
18
2
17
H
dEC
H
dEC
dEC
×
+
×
+
=
ACC, dEC indicate the set time in Drive group.
Accel/Decel Disable
Group
Code Parameter Name
Setting Range
Initial
Unit
I/O group
I17
[Multi-function input terminal
P1 define]
-
0 ~29
0
~
~
I24
[Multi-function input
terminal P8 define]
24
7
Select one terminal among Multi-function input terminals 1-8 to define Accel/Decel disable.
If P8 is selected, set I24 to 24 to activate this function.
Freq.
P8
Operating
command
☞
Note: If Target
Frequency is below Max
Frequency, the waveform
will be shown with the top
portion cut out.
Freq
H17
H17
H18
H18
Accel/decel
Ref Freq
Target Freq