7-22
LED
display Parameter name
Min/Max
range
Description
Factory
defaults
Adj.
during
run
I56
[Fault relay
output]
0 ~ 7
When
setting the
H26–
[Number of
auto restart
try]
When the
trip other
than low
voltage
trip occurs
When the
low
voltage trip
occurs
2
O
Bit 2
Bit 1
Bit 0
0
-
-
-
1
-
-
2
-
-
3
-
4
-
-
5
-
6
-
7
I57
[Output terminal
select when
communication
error occurs]
0 ~ 3
Multi-function
relay
Multi-function
output terminal
0
O
Bit 1
Bit 0
0
-
-
1
-
2
-
3
I59
[Communication
protocol select]
0 ~ 1
Set communication protocol.
0
X
0 Modbus RTU
1 ES BUS
I60
[Inverter number] 1 ~ 250 Set for RS485 communication
1
O
I61
[Baud rate]
0 ~ 4
Select the Baud rate of the RS485.
3
O
0 1200 [bps]
1 2400 [bps]
2 4800 [bps]
3 9600 [bps]
4 19200 [bps]
I62
[Drive mode
select after loss
of frequency
command]
0 ~ 2
It is used when freq command is given
via V1 /I terminal or RS485.
0
O
0 Continuous operation at the
frequency before its command is lost.
1 Free Run stop (Output cut-off)
2 Decel to stop
Summary of Contents for Sinus M
Page 10: ......
Page 15: ...1 5 Notes...
Page 16: ......
Page 50: ...6 4 Notes...
Page 78: ...8 4 Notes...
Page 114: ...10 14 Normal PID block diagram H54 0...
Page 115: ...10 15 Process PID block diagram H54 1...
Page 150: ...10 50 Notes...
Page 174: ......
Page 192: ...13 18 Notes...
Page 204: ......
Page 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...