10-31
10.13 Operating sound select (Carrier frequency change)
Group
Display
Parameter Name
Setting
Range
Default Unit
Function
group 2
H39
[Carrier frequency]
-
1 ~ 15
3
kHz
This parameter affects the sound of the inverter during operation.
H39
When setting carrier frequency
high
Motor sound reduced
Inverter heat loss increased
Inverter noise increased
Inverter leakage current
increased
10.14 2
nd
motor operation
Group Display
Parameter Name
Setting
Range
Default Unit
Function
group 2 H81
[2nd motor accel time]
-
0 ~ 6000
5.0
sec
H82
[2nd motor decel time]
-
0 ~ 6000
10.0
sec
H83
[2nd motor base freq.]
-
30 ~ 400
60.00
Hz
H84
[2nd motor V/F pattern]
-
0 ~ 2
0
H85
[2nd motor Positive torque
boost]
-
0 ~ 15
5
%
H86
[2nd motor Negative torque
boost]
-
0 ~ 15
5
%
H87
[2nd motor stall prevention
level]
-
30 ~ 150
150
%
H88
[2nd motor electronic thermal
level for 1 min]
-
50 ~ 200
150
%
H89
[2nd motor electronic thermal
level for continuous operation] -
50 ~ 200
100
%
H90
[2nd motor rated current]
-
1 ~ 50
26.3
A
I/O
group
I17
[Multi-function Input terminal
P1Function select]
-
0 ~ 29
0
~
~
I24
[Multi-function Input
terminal P8 Function select] 12
7
Set the terminal among Multi-function input P1 through P5 for second motor
operation.
To define the terminal P5 as second motor operation, set I24 to 12.
Summary of Contents for Sinus M
Page 10: ......
Page 15: ...1 5 Notes...
Page 16: ......
Page 50: ...6 4 Notes...
Page 78: ...8 4 Notes...
Page 114: ...10 14 Normal PID block diagram H54 0...
Page 115: ...10 15 Process PID block diagram H54 1...
Page 150: ...10 50 Notes...
Page 174: ......
Page 192: ...13 18 Notes...
Page 204: ......
Page 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...