6-3
Frequency setting via potentiometer & operating via the Run key
1
-. Apply AC input power to the inverter.
2
-. When 0.00 is displayed, press the Up (
) key three times.
3
-. “drv” is displayed. Operating method is selectable.
-. Press the Ent (
) key.
4
-. Check the present operating method (“1”: Run via control terminal).
-. Down (
) key once.
5
-. After setting “0”, press the Ent (
) key. When 0 is blinking, press the Ent
again.
6
-. “drv” is displayed after “0” is blinking. Operation method is set via the Run key
on the keypad. -. Press the Up (
) key once.
7
-. Different frequency setting method is selectable.
-. Press the Ent (
) key.
8
-. Check the present frequency setting method (“
0
” is run via keypad).
-. Press the Up (
) key three times.
9
-. After checking “
3
” (frequency setting via potentiometer), press the Ent (
) key
twice.
10
-. “
Frq
” is displayed. Frequency is set via the potentiometer.
-. Turn the potentiometer to set to 10.0 Hz in either Max or Min direction.
11
-. Press the Run key on the keypad.
-. RUN lamp begins to blink with FWD lamp lit and accelerating frequency is
displayed on the LED.
-. When run frequency 10Hz is reached,
10.00
is displayed as shown left.
-. Press the STOP/RST key.
12
-. RUN lamp begins to blink and decelerating frequency is displayed on the
LED.
-. When run frequency is reached to 0Hz, Run and FWD lamp turn off and
10.00
is displayed.
R
S
G
U
V
W
T
Keypad
Motor
VR
V1
CM
Freq.
Run key
10 Hz
STOP/RST key
Wiring
Operating pattern
Summary of Contents for Sinus M
Page 10: ......
Page 15: ...1 5 Notes...
Page 16: ......
Page 50: ...6 4 Notes...
Page 78: ...8 4 Notes...
Page 114: ...10 14 Normal PID block diagram H54 0...
Page 115: ...10 15 Process PID block diagram H54 1...
Page 150: ...10 50 Notes...
Page 174: ......
Page 192: ...13 18 Notes...
Page 204: ......
Page 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...