7-24
LED
display Parameter name
Min/Max
range
Description
Factory
defaults
Adj.
during
run
I82
[Brake open
current]
0~180
[%]
Sets current level to open the brake.
It is set according to H33’s (motor
rated current) size
50.0
O
I83
[Brake open
delay time]
0~10
[s]
Sets Brake open delay time.
1.00
X
I84
[Brake open FX
frequency]
0~400
[Hz]
Sets FX frequency to open the brake 1.00
X
I85
[Brake open RX
frequency]
0~400
[Hz]
Sets RX frequency to open the brake 1.00
X
I86
[Brake close
delay time]
0~19
[s]
Sets delay time to close the brake
1.00
X
I87
[Brake close
frequency]
0~400
[Hz]
Sets frequency to close the brake
2.00
X
I88
Fire Mode
Frequency
0.0 ~
400.0 Hz
Command frequency when in Fire
Mode
50.0Hz
O
I89
PID F/B minimum
scaling factor
0.0 ~
100.0
PID F/B minimum scaling factor
0.0
O
I90
PID F/B
maximum scaling
factor
0.0 ~
100.0
PID F/B maximum scaling factor
100.0
O
I91
A, B Contact type
selection
0
A Contact (Normal open)
0
O
1
B Contact (Normal Close)
I92
MO On delay
0.0~10.0
sec
MO Contact On delay time
0.0 sec
X
I93
MO Off delay
0.0~10.0
sec
MO Contact Off delay time
0.0 sec
X
I94
30A,B,C On
delay
0.0~10.0
sec
30 A,B,C Contact On delay time
0.0 sec
X
I95
30A,B,C Off
delay
0.0~10.0
sec
30 A,B,C Contact Off delay time
0.0 sec
X
I96
Fire Mode
Evidence
0 ~ 1
0 : No trip during fire mode
-
-
1 : Trip during fire mode
Summary of Contents for Sinus M
Page 10: ......
Page 15: ...1 5 Notes...
Page 16: ......
Page 50: ...6 4 Notes...
Page 78: ...8 4 Notes...
Page 114: ...10 14 Normal PID block diagram H54 0...
Page 115: ...10 15 Process PID block diagram H54 1...
Page 150: ...10 50 Notes...
Page 174: ......
Page 192: ...13 18 Notes...
Page 204: ......
Page 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...