15-5
15.2 Inverter Efficiency and Heating Loss
Measured conditions: 50Hz; 100% Current Load; Default Carrier Frequency.
Note:
The inverter efficiency is computed by considering the SMPS power consumption.
SINUS M ■ ■ ■ 2S/T
BA2K2
0001 0002 0003 0005 0007 0011 0014 0017 0020 0025 0030
Efficiency
%
95.3 95.5 98.4 97.2 97.2 98.4 98.9 97.0 95.2 95.7 96.2
Heating Loss
W
13
28
18
56
106
73
70
290
683
759
799
kcal
11
24
15
48
91
63
61
249
587
799
687
SINUS M ■ ■ ■ 4T
BA2K2
0001 0002 0003 0005 0007 0011 0014 0017 0020 0025 0030
Efficiency
%
96.2 96.2 97.5 97.6 97.5 98.2 98.3 97.0 95.7 95.7 95.2
Heating Loss
W
9
22
32
47
94
84
113
293
608
759 1019
kcal
8
19
27
40
81
72
97
252
523
652
877