12.8 DB Resistor Enable Duty setting
Group
Code Parameter
Set
Range
Initial
Unit
Function
group 2
H75
[Enable duty limit]
1
0 ~ 1
1
H76
[Enable duty]
-
0 ~ 30
10
%
Set H75 to 1.
Set %ED (Enable Duty) in H76.
H75: DB resistor ED limit setting
0
No limit
Caution:
Take caution when DB resistor is used over its Watt rating. Fire may result from
resistor overheat. When resistor having heat detection sensor is used, sensor
output can be used as external trip signal in multi-function input.
1
ED is limited as the setting in H76.
H76: set the resistor operating rate (%ED) in one sequence of operation. Continuous usage rate is Max
15 sec and usage signal is not issued over 15 sec.
Ex 1)
[%]
100
_
_
_
_
_
76
×
+
+
+
=
stop
T
dec
T
steady
T
acc
T
dec
T
H
Where:
T_acc: Acceleration time to reach the set freq.
T_steady: Time for constant speed operation at setting freq.
T_dec: Time to decelerate to lower frequency set.
T_stop: waiting time at motor stopped before operation again.
Freq.
T_acc T_steady T_dec
T_stop
Ex 2)
[%]
100
2
_
_
1
_
_
_
76
×
+
+
+
=
steady
T
acc
T
steady
T
dec
T
dec
T
H
Freq.
T_acc
T_steady1
T_dec
T_steady2
Summary of Contents for Sinus M
Page 10: ......
Page 15: ...1 5 Notes...
Page 16: ......
Page 50: ...6 4 Notes...
Page 78: ...8 4 Notes...
Page 114: ...10 14 Normal PID block diagram H54 0...
Page 115: ...10 15 Process PID block diagram H54 1...
Page 150: ...10 50 Notes...
Page 174: ......
Page 192: ...13 18 Notes...
Page 204: ......
Page 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...