7-2
LED
display
Parameter
name
Setting
range
Description
Factory
defaults
Adj.
during
run
rPM
[Motor RPM]
Displays the number of Motor RPM.
-
-
dCL
[Inverter DC
link voltage]
Displays DC link voltage inside the
inverter.
-
-
vOL
[User display
select]
This parameter displays the item
selected at H73- [Monitoring item
select].
vOL
-
vOL
Output voltage
POr
Output power
tOr
Torque
nOn
[Fault
Display]
Displays the types of faults, frequency
and operating status at the time of the
fault
-
-
drC
[Direction of
motor
rotation
select]
F, r
Sets the direction of motor rotation
when drv - [Drive mode] is set to 0.
F
O
F
Forward
r
Reverse
drv2
1)
[Drive mode
2]
0 ~ 3
0 Run/Stop via Run/Stop key on the
keypad
1
X
1 Terminal
operation
FX: Motor forward run
RX: Motor reverse run
2
FX: Run/Stop enable
RX: Direction
3
RS485
Communication
Frq2
1)
[Frequency
setting
method 2]
0 ~ 7
0 Digital
Keypad setting 1
0
X
1
Keypad setting 2
2 Analog
V1 1: –10 ~ +10 [V]
3
V1 2: 0 ~ +10 [V]
4
Terminal I: 0 ~ 20
[mA]
5
Terminal V1 setting 1
+ Terminal I
6
Terminal V1 setting 2+
Terminal I
7 Digital
RS485
Communication
1)
:
Displayed only when one of the Multi-function input terminals 1-8 [I17~I24] is set to “22”.
Summary of Contents for Sinus M
Page 10: ......
Page 15: ...1 5 Notes...
Page 16: ......
Page 50: ...6 4 Notes...
Page 78: ...8 4 Notes...
Page 114: ...10 14 Normal PID block diagram H54 0...
Page 115: ...10 15 Process PID block diagram H54 1...
Page 150: ...10 50 Notes...
Page 174: ......
Page 192: ...13 18 Notes...
Page 204: ......
Page 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...