10-41
Select 1 and 2 for F70
The center value of analogue input (selected by the set value of I6~I15) as standard, if the
input is big it gets (+), if small (-) and gets reflected in the output frequency as the ratio set
in F71.
Select 3 for F70
0V as standard, if analog input voltage is big, it gets (+), if small (-) and gets reflected in
the output frequency as the rate set in F71.
1st/2nd
Frequency Select
Communi-
cation
I/O Group
I 6, 11
Analog Input
Filter
I/O Group
I 7 ~ I15
Analog Input
Scale
V1_2
0 ~ +10 [V]
I
0 ~ 20 [mA]
Keypad or
Remote Keypad
Drive Group
Frq/Frq2
0
1
2
3
4
5
6
7
8
Keypad Setting 2
V1_2 : 0 ~ 10V
I : 0 ~ 20mA
1
3
4
7
Keypad Setting 1
0
Communication
8
Mult-step Freq.
Mult-step
Freq. Select
Digital Input
Filter
P1
P2
P3
P4
P5
P6
P7
P8
I 27
I/O Group
I17 ~ I24
5,6,7
I/O Group
St1~St3
I30~I33
Drive Group
I/O Group
V1_2 Mode
I Mode
1
2
NONE
0
Func. Group 1
F70 : DRAWMODE
V1_2
0 ~ +10 [V]
I
0 ~ 20 [mA]
I/O Group
I 6, 11
I/O Group
I3 ~ I15
Center Freq.
Func. Group 1
F71
K
Final Reference
Frequency
V1_1 Mode
3
V1_1
-10 ~ 10 [V]
Func. Group 1
F70
Func. Group 1
F70
F70 = 3
I17~I24
I/O Group
JOG Frequency
V1_1 : -10 ~ 10V
2
DRAW operation example
If draw operation is set to 30Hz, F70=3(V1: –10V ~10V), F71=10.0% selected, (I3~I15 = factory
defaults) Frequency that gets changed by DRAW operation is 27Hz(V1=–10V) ~33Hz(V1=10V)
CAUTION
When operating DRAW, set command frequency to FRQ/FRQ2 and set the rest of it from F70
(DRAW mode select). For example, if FRQ=2(V1) and F70=1(V1), it does not operate.
Summary of Contents for Sinus M
Page 10: ......
Page 15: ...1 5 Notes...
Page 16: ......
Page 50: ...6 4 Notes...
Page 78: ...8 4 Notes...
Page 114: ...10 14 Normal PID block diagram H54 0...
Page 115: ...10 15 Process PID block diagram H54 1...
Page 150: ...10 50 Notes...
Page 174: ......
Page 192: ...13 18 Notes...
Page 204: ......
Page 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...