10-28
10.11 Speed search
Group
Display
Parameter Name
Setting
Range
Default Unit
Function
group 2
H22
[Speed search select]
-
0 ~ 15
0
H23
[Current level]
-
80 ~ 200 100
%
H24
[Speed search P gain]
-
0 ~ 9999
100
H25
[Speed search I gain]
-
200
I/O group
I54
[Multi-function output
terminal select]
15
0 ~ 18
12
I55
[Multi-function relay select] 15
17
This is used to prevent possible fault occurring if the inverter supplies a load in movement
(For example if the inverter is disabled, the motor idles; if the inverter is enabled when the
motor is idling, it will search the motor speed).
The inverter estimates the motor rpm based on output current when speed search is
active.
The following table shows 4 types of Speed search selection.
H22
Speed search H20
is set 1 [Power ON
start]
Speed search after
Instant Power
Failure restart
Speed search if
H21 is set 1
[Restart after fault
reset]
Speed search
during Acceleration
Bit 3
Bit 2
Bit 1
Bit 0
0
-
-
-
-
1
-
-
-
2
-
-
-
3
-
-
4
-
-
-
5
-
-
6
-
-
7
-
8
-
-
-
9
-
-
10
-
-
11
-
12
-
-
13
-
14
-
15
H23: Limits current during Speed search. Set as the percent of H33.
H24, H25: Speed search is managed by a PI control. Adjust P gain and I gain corresponding to the load
characteristics.
I54, I55: Signal of active Speed search is given to Multi-function output terminal (MO) and Multi-function
relay output (3ABC).
Summary of Contents for Sinus M
Page 10: ......
Page 15: ...1 5 Notes...
Page 16: ......
Page 50: ...6 4 Notes...
Page 78: ...8 4 Notes...
Page 114: ...10 14 Normal PID block diagram H54 0...
Page 115: ...10 15 Process PID block diagram H54 1...
Page 150: ...10 50 Notes...
Page 174: ......
Page 192: ...13 18 Notes...
Page 204: ......
Page 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...