3-1
CHAPTER 3 - WIRING
3.1 Terminal wiring (Control I/Os)
Note:
Wiring relates to the NPN configuration (see PNP/NPN selection and connector for
communication option).
T/M
Description
MO
Multi-function open collector output
MG
MO Common
24
24V output
P1
MF input terminal
(factory setting)
FX: Forward run
P2
RX: Reverse run
CM
Input signal common
P3
MF input terminal
(factory setting)
BX: Emergency stop
P4
RST: Trip reset
P5
JOG: Jog operation
CM
Input signal common
P6
MF input terminal
(factory setting)
Multi-step freq.-Low
P7
Multi-step freq.-Middle
P8
Multi-step freq.-High
VR
10V power supply for potentiometer
V1
Freq. Setting Voltage signal input: –10~10V
I
Freq. Setting Current signal input: 0~20mA
AM
Multi-function analog output signal: 0~10V
3A
Multi-function
relay output
terminal
A contact output NO
3B
B contact output NC
3C
A/B contact common
S+
RS485 communication terminal
S-
※
For connection to Remote Option or
parameter copy.
Summary of Contents for Sinus M
Page 10: ......
Page 15: ...1 5 Notes...
Page 16: ......
Page 50: ...6 4 Notes...
Page 78: ...8 4 Notes...
Page 114: ...10 14 Normal PID block diagram H54 0...
Page 115: ...10 15 Process PID block diagram H54 1...
Page 150: ...10 50 Notes...
Page 174: ......
Page 192: ...13 18 Notes...
Page 204: ......
Page 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...