Wiring
58
FQ2-S/CH User’s Manual
*1:
Leave all signal terminals that are labeled “NC” open.
*2:
You can select whether to turn the external lighting ON (Positive) or OFF (Negative) when the signal turns ON. (The setting is called the
strobe output polarity.)
FQ2-S/CH Series User's Manual for Communications Settings
(Cat. No. Z338)
Section 2 Controlling Operation and Outputting Data with a Parallel Connection
*3:
This control signal is used to turn ON external lighting when an image is taken. Connect this signal to external lighting.
*4:
This signal is output to an external device when exposure of the imaging elements is completed. If you want to move the Sensor to the
next measurement location after a measurement is completed, move the Sensor only after this signal turns ON.
Shutter Output Signal (SHTOUT)
Trigger input (TRIG)
Shutter time
Imaging element
shutter signal
SHTOUT
10 ms
Trigger delay
ON
OFF
ON
OFF
ON
OFF
The SHTOUT signal turns ON for approximately 10 ms (fixed) when the shutter time (exposure period) elapses after
the trigger is input from an external device.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......