Adjusting Judgement Parameters during Operation
362
FQ2-S/CH User’s Manual
6-4 Adjusting Judgement Parameters during Operation
FQ2-S1
FQ2-S2
FQ2-S3
FQ2-S4
FQ2-CH
This Sensor enables judgment parameters to be adjusted while measurements are being performed.
Downtime can be eliminated with this feature because the production line does not have to be stopped while
making adjustments.
Preparations
This function is switched OFF as a Default to prevent it from inadvertently working during operation.
Turn ON the function if you want to use it.
(Setup
Mode)
−
[Sensor settings]
−
[Adjustment mode in Run]
1
Press [ON].
Changing the Judgment Parameters in Run Mode
This section describes how to change the judgment parameters without stopping measurement in Run Mode.
Run Mode
1
Select the inspection item or position compensation item for which you want to adjust the
judgment parameters using the
and
Buttons.
2
Press [ ] – [Adjust judgement].
3
Press the parameters and change the values of
the judgment conditions for them with the slid-
er.
4
Press [OK].
The judgement results with the changed judg-
ment parameters will appear.
The changed judgment parameters will not be reflected in the measurement result until [OK] is pressed.
Important
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......