Inspecting with the Edge Position Inspection Item
280
FQ2-S/CH User’s Manual
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via the Ethernet or
used in calculations.
4-18 Calculations and Judgments Using Inspection Item Data
Expression
text string
Data name
Description
Data range
JG
Judgement
−
2: No judgement (not measured)
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
This is the judgment result.
X
Position X
−
99999.9999to 99999.9999
This is the X coordinate of the measured
edge position.
Y
Position Y
−
99999.9999 to 99999.9999
This is the Y coordinate of the measured
edge position.
SX
Ref. position X
(reference position X)
−
99999.9999 to 99999.9999
This is the X coordinate of the edge position
when a range is set.
SY
Ref. position Y
(reference position Y)
−
99999.9999 to 99999.9999
This is the Y coordinate of the edge position
when a range is set.
DF
D. position
(difference in position)
−
99999.9999 to 99999.9999
This is the offset from the measured refer-
ence position.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......