Inspecting with the Area Inspection Item
FQ2-S/CH User’s Manual
309
4
Setting Up Inspect
ions
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via the Ethernet or
used in calculations.
4-18 Calculations and Judgments Using Inspection Item Data: p. 323
Measurement Data That Can Be Logged for Area
The following values can be logged as measurement data.
* When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 392
Expression
text string
Data name
Description
Data range
JG
Judgement
−
2: No judgement (not measured)
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
This is the judgement result.
AR
Area
0 to 999999999.9999
This is the area in the measurement region
with the specified color.
X
Gravity X
−
99999.9999 to 99999.9999
This is the X coordinate of the center of the
measurement area with the specified color.
Y
Gravity Y
−
99999.9999 to 99999.9999
This is the Y coordinate of the center of the
measurement area with the specified color.
SA
Reference area
0 to 999999999.9999
This is the area with the specific color to be
measured when a range is set.
SX
Ref. point X
(reference point X)
−
99999.9999 to 99999.9999
This is the X coordinate of the center of
gravity when a range is set.
SY
Ref. point Y
(reference point Y)
−
99999.9999 to 99999.9999
This is the Y coordinate of the center of
gravity when a range is set.
Measured item
Range of value
Description
Judgement
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
This is the measurement judgement results.
Area
0 to 99999.9999
This is the measured color area.
Gravity X
−
99999.9999 to 99999.9999
This is the detected center of gravity X coordinate.
Gravity Y
−
99999.9999 to 99999.9999
This is the detected center of gravity Y coordinate.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......