
Logging Measurement Data and Image Data
392
FQ2-S/CH User’s Manual
7-6 Logging Measurement Data and Image Data
FQ2-S1
FQ2-S2
FQ2-S3
FQ2-S4
FQ2-CH
There are two ways to log data.
Recent results logging:
Data is temporarily saved in memory inside the Sensor.
File logging:
Large amounts of data are saved in SD cards or other external media.
The amounts and types of data that can be logged depend on the logging method that is used, as shown in the
following table.
*1: For recent results logging, the oldest data is overwritten when the maximum number of saved data items is exceeded.
*2: This limit is for one data item.
If more than one data item is logged at the same time, logging can be performed as long as the total number of data items
in all logged data is 32,000 or less.
Logged data
Logged quantity
Recent results logging
*1
File logging
Statistical data
One value (The average value of the mea-
surement results in the collected measure-
ment data is continuously updated.)
Not possible.
Measurement data
1,000 measurement values max.
*2
Up to the capacity of the external memory
Image data
20 images max.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......