Inspecting with the Labeling Inspection Item
316
FQ2-S/CH User’s Manual
• Sensors with Monochrome Cameras (or for a Color Gray Filter)
1
Press [ ]
−
[Binary level] on the right of the display.
2
Specify the range of brightness to detect,
and then press [OK].
Specify the range of brightness to convert to a bina-
ry image. Measurement is performed after the im-
age taken by the camera in 256-color grayscale is
converted to a binary image. Then, white pixels are
measured.
3
Press [OK].
4
Press [TEACH].
5
Press [Back] to end teaching.
Making the Extraction Results Easier to Check
• You can invert the black/white extraction results.
Press
[ ]
−
[Reverse] and select [Yes].
• You can select whether to display a binary image.
Press
[ ]
−
[Binary image display] and select [OFF] or [ON].
Note