![background image](http://html1.mh-extra.com/html/omron/fq2-s-ch-series/fq2-s-ch-series_user-manual_742878451.webp)
Menu Tables
FQ2-S/CH User’s Manual
449
Appe
ndi
ce
s
9
In
spect
ion
Se
tt
ings
Jud
gemen
t
2D
-code
Num. of char.
Displays the number of characters that
were read.
---
---
Characters
Displays the character string that was
read.
---
---
Overall quality
Displays the evaluation value of over-
all quality.
0 to 4
---
Decode
Displays the evaluation value of
decode.
---
---
Cell Contrast
Displays the evaluation value of cell
contrast.
---
---
Cell Modulation
Displays the evaluation value of cell
modulation.
---
---
Fixed pattern
damage
Displays the evaluation value of fixed
pattern damage.
---
---
Axial nonunifor-
mity
Displays the evaluation value of axial
nonuniformity.
---
---
Grid nonunifor-
mity
Displays the evaluation value of grid
nonuniformity.
---
---
Unused err.
Corr.
Displays the evaluation value of
unused error correction.
---
---
Print scale
Displays the evaluation value of the
print scale.
---
---
Print scale X
Displays the evaluation value of print
scale X.
---
---
Print scale Y
Displays the evaluation value of print
scale Y.
---
---
2D-code(
D
P
M)*
3
Contrast
Sets the upper and lower limits of the
contrast that is to be judged as OK.
0 to 100
(Defaults: lower limit: 0
upper limit: 100)
Scene
Focus
Sets the upper and lower limits of the
focus that is to be judged as OK.
0 to 100
(Defaults: lower limit: 0
upper limit: 100)
Scene
Cell Recog. Rate
Sets the upper and lower limits of the
cell recognition rate that is to be
judged as OK.
0 to 100
(Defaults: lower limit: 0
upper limit: 100)
Scene
Num. of char.
Displays the number of characters that
were read.
---
---
Characters
Displays the character string that was
read.
---
---
Cell size
Outputs the number of pixels per cell
of the scanned code.
---
---
Overall quality
Displays the evaluation value of over-
all quality.
0 to 4
---
Decode
Displays the evaluation value of
decode.
---
---
Cell Contrast
Displays the evaluation value of cell
contrast.
---
---
Cell Modulation
Displays the evaluation value of cell
modulation.
---
---
Fixed pattern
damage
Displays the evaluation value of fixed
pattern damage.
---
---
Axial nonunifor-
mity
Displays the evaluation value of axial
nonuniformity.
---
---
Grid nonunifor-
mity
Displays the evaluation value of grid
nonuniformity.
---
---
Unused err.
Corr.
Displays the evaluation value of
unused error correction.
---
---
Menu command
Description
Setting range
Data
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......