Inspecting with the Area Inspection Item
308
FQ2-S/CH User’s Manual
Changing the Area Detection Conditions
You can fill in the area detected through color extraction or binary conversion to perform a stable extraction of
the areas and their characteristics or to mark only areas inside the measurement region for inspection.
[Inspect]
−
[Inspection]
−
[Aria]
−
[Modify]
−
[Details] Tab Page
−
[Meas. Parameter]
Increasing Processing Speed for Area
Make the measurement region smaller to reduce the processing time.
Changing the measurement region: p. 227
1
Press [Fill profile] and select [Filling up holes]
or [Fill Outline].
Parameter
Setting
Description
Fill profile
• None (Default)
• Fill Outline
• Filling up holes
None: Holes are not filled.
Filling up holes: Processes areas that are surrounded by the specified color,
like in the shape of a donut, as the specified color.
Fill Outline:
Measures the image between the first extracted point and the last extracted
point in the X axis direction in the measurement area as the extracted color.
Because filling is performed only in the X axis direction, this method is faster
than filling up holes.
Input Image
Filled Image
Input Image
Image Following Fill Outline
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......