External Reference Parameters
FQ2-S/CH User’s Manual
499
Appe
ndi
ce
s
9
120
Mea-
sure-
ment
condi-
tions
Position compensation pre-
cision
Set / Get
0: None, 1: Bilinear
0
---
---
122
Position compensation
image
Set / Get
0: Camera image,
1: Previous image
1
---
---
140
Edge color specification 0
Set / Get
0: No edge color specification,
1: Edge color specification
0
---
---
141
Edge color R0
Set / Get
0 to 255
255
---
---
142
Edge color G0
Set / Get
0 to 255
255
---
---
143
Edge color B0
Set / Get
0 to 255
255
---
---
147
Density change 0
Set / Get
0: Color IN, 1: Color OUT
0
---
---
149
Edge level 0
Set / Get
0 to 100
50
---
---
150
Noise level 0
Set / Get
0 to 442
5
---
---
153
Monochrome density
change 0
Set / Get
(Monochrome Cameras)
0: Light to Dark, 1: Dark to Light
0
---
---
154
Edge level absolute value
Set / Get
0 to 442
20
---
---
155
Edge level specification
method
Set / Get
0:%
1: Absolute value
0
---
---
157
Measurement method 0
Set / Get
(Monochrome Cameras)
0: Projection
1: Differentiation
0
---
---
158
Edge level absolute value
(Monochrome Cameras)
Set / Get
0 to 255
20
---
---
160
Edge color specification 0
Set / Get
0: No edge color specification,
1: Edge color specification
0
---
---
161
Edge color R1
Set / Get
0 to 255
255
---
---
162
Edge color G1
Set / Get
0 to 255
255
---
---
163
Edge color B1
Set / Get
0 to 255
255
---
---
167
Density change 1
Set / Get
0: Color IN, 1: Color OUT
0
---
---
169
Edge level 1
Set / Get
0 to 100
50
---
---
170
Noise level 1
Set / Get
0 to 442
5
---
---
173
Monochrome density
change 1
Set / Get
(Monochrome Cameras)
0: Light to Dark
1: Dark to Light
0
---
---
177
Measurement method 1
Set / Get
(Monochrome Cameras)
0: Projection
1: Differentiation
0
---
---
180
Judge-
ment
condi-
tions
Edge position X upper limit
0
Set / Get
−
99,999.9999 to 99,999.9999
99,999.99
99
---
Judgement
condition
181
Edge position X lower limit
0
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.99
99
---
Judgement
condition
182
Edge position Y upper limit
0
Set / Get
−
99,999.9999 to 99,999.9999
99,999.99
99
---
Judgement
condition
183
Edge position Y lower limit
0
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.99
99
---
Judgement
condition
185
Edge position X upper limit
1
Set / Get
−
99,999.9999 to 99,999.9999
99,999.99
99
---
Judgement
condition
186
Edge position X lower limit
1
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.99
99
---
Judgement
condition
Exter-
nal ref-
erence
number
Category
Data name
Set / Get
Data range
Default Expres-
sion text
string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......