Inspection Data that Can be Logged
The following values can be logged as inspection data.
When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 392
If an Error Occurs
If a teaching error occurs
If scanning of the 2D code fails, a teaching error message appears.
It is likely that low contrast caused unstable scanning.
Adjust the brightness to increase the contrast of the 2D code.
Adjusting the Brightness: p. 77
Inspection item
Value range
Description
Judgement
−
2: No judgement (not measured)
0: Judgement is OK
−
1: Judgement is NG
−
16: Measurement timeout error
This is the judgment result from the measurements.
Contrast
0 to 100
Outputs the contrast.
Focus
0 to 100
Outputs the focus.
Cell recognition rate
0 to 100
Outputs the cell recognition rate.
Num. of char.
0 to 1024
Outputs the number of characters that were detected.
Index
−
2: No verification pattern, or read-
ing error
−
1: Verification is NG,
0 to 31: Master data No.
Outputs the index.
Cell size
Depends on the size of the code.
Outputs the number of pixels per cell of the scanned
code.
Overall quality
0 to 4
Outputs the evaluation value of overall quality.
Decode
0 to 4
Outputs the evaluation value of decode.
Cell contrast
0 to 4
Outputs the evaluation value of the contrast.
Cell modulation
0 to 4
Outputs the evaluation value of cell modulation.
Fixed pattern damage
0 to 4
Outputs the evaluation value of fixed pattern damage.
Axial nonuniformity
0 to 4
Outputs the evaluation value of axial nonuniformity.
Grid nonuniformity
0 to 4
Outputs the evaluation value of grid nonuniformity.
Unused err. Corr.
0 to 4
Outputs the evaluation value of unused error correc-
tion.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......