Adjusting Image Quality
76
FQ2-S/CH User’s Manual
3-3 Adjusting Image Quality
FQ2-S1
FQ2-S2
FQ2-S3
FQ2-S4
FQ2-CH
Adjusting the Focus
[Image]
−
[Camera setup]
• Turn the focus adjustment screw clockwise or counterclockwise a little bit to make sure that it has not already
reached the dead stop. Do not force the screw if it does not rotate anymore. This will damage the Sensor.
• Do not turn the focus adjustment screw with a force that is greater than 0.1 N·m. This may damage it.
1
Display the Camera Setup Display.
The focus can be seen as a numerical value.
The higher the value, the better the focus.
2
Adjust the focus of the Sensor while checking
the image and focus value on the Touch Finder.
For a Sensor with Built-in Lighting, manually adjust
the focus using the focus adjustment screw on the
Sensor.
In the Default settings, the field of view is set to the
narrowest setting.
For a Sensor with a C-mount, use the focus ring on
the lens to adjust the focus of the image.
3
Press [Back].
Focus Level
(The field of view will widen.)
Turn the screw counterclockwise
to focus on objects at a distance.
(The field of view will
narrow.)
Turn clockwise to focus on closer objects.
Focus adjustment screw
Sensor with Built-in Lighting
Important
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......