Menu Tables
FQ2-S/CH User’s Manual
461
Appe
ndi
ce
s
9
In/Out Tab Page
Menu command
Description
Setting range
Data
Log sett
ing
Statistical data
Sets whether to record the number of
measurements and the number of NG
overall judgments.
ON (Default)
OFF
System
Image logging
Sets the parameter to log measurement
image data.
All
Only NG
None (Default)
System
Data log-
ging
Condition
Sets the parameter to log measurement
data from inspection items.
All
Only NG
None (Default)
System
Select data
You can select the parameters to log
from the parameters in the filter items,
position compensation items, inspection
items and expression that are set.
Parameter names for the filter items
position compensation items, inspection
items and expression that are set
System
Delete Log
Resets the log data without turning OFF
the power supply.
---
---
I/
O s
e
tt
in
g
I/
O s
e
tt
in
g
Ou
tp
u
t
OUT0
to
OUT2
Control
signal
Specify the output signal to OUT0 to
OUT2.
When model FQ-SDU is connected,
OUT0 to OUT2 are not displayed.
OR
(Total judgement (Default assignment:
OUT0))
BUSY
ERROR
(Default assignment: OUT2)
READY (Default assignment: OUT1)
RUN
STG
System
---*
1
Item
judge-
ment
OR0 (Item0 judgement) to OR31 (Item31
judgement)
Expres-
sion
judge-
ment
Exp.0 judgement to EXP. 31 judgement
OR output
OK: ON
NG: ON (Default)
System
---*
1
Output mode
You can set the output mode for the OR
signal and for output signals to which
judgements are assigned.
One-shot output
Level output (Default)
System
---*
1
Output delay
When one-shot output mode is selected,
this parameter sets the delay from when
measurement processing is completed
until when the OR signal turns ON.
0 to 1,000 ms (Default: 0 ms)
System
---*
1
Output time
When one-shot output mode is selected,
this parameter sets the time that the OR
signal is ON.
1 to 1,000 ms (Default: 5 ms)
System
BUSY output
Specifies when to turn OFF the BUSY
signal after starting measurement pro-
cessing.
Measurement (Default)
Data logging
Image logging
Result display
System
---*
1
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......