Reading with OCR
FQ2-S/CH User’s Manual
173
4
Setting Up Inspect
ions
Error Messages during Registration
• Failed to register data. Character format is wrong.
The format or the number of characters did not match between the read character string and the registered charac-
ter string. Correct the character string to register.
• Failed to register data. Character size is too small
You can register characters that are 30
×
30 pixels or larger in the dictionary. Change the settings of the Sensor to
increase the size of the characters.
• Extraction error
Failed to extract the characters. Check the measurement parameter settings and the read region.
• Excess char. num
An attempt was made to register more than 10 characters. Delete the data that does not need to be registered.
12
The extracted characters will be displayed
on the upper left of the display.
If characters are not displayed even you touch
[Extraction] button, back Step 7 and retry to.
13
Press [OK] to register the characters.
14
The characters are registered for the corre-
sponding character type.