External Reference Parameters
534
FQ2-S/CH User’s Manual
Edge Position (FQ2-S1/S2/S3 series or FQ2-S4 series only)
700
Display
settings
Correlation display
Set / Get 0: Display
1: Do not display
0
---
---
701
Position X display
Set / Get 0: Display
1: Do not display
0
---
---
702
Position Y display
Set / Get 0: Display
1: Do not display
0
---
---
703
Measurement angle
display
Set / Get 0: Display
1: Do not display
0
---
---
704
Count display
Set / Get 0: Display
1: Do not display
0
---
---
800
Position X display pat-
tern
Set / Get 0: Absolute value
1: Relative value
0
---
---
801
Position Y display pat-
tern
Set / Get 0: Absolute value
1: Relative value
0
---
---
802
Measurement angle
display pattern
Set / Get 0: Absolute value
1: Relative value
0
---
---
Exter-
nal ref-
erence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion
text
string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result
Judgement
Get only
−
2: No judgement
(not measured)
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
−
2
JG
Logged data
5
Edge position X
Get only
−
99,999.9999 to 99,999.9999
0
X
Logged data
6
Edge position Y
Get only
−
99,999.9999 to 99,999.9999
0
Y
Logged data
7
Standard position X
Get only
−
99,999.9999 to 99,999.9999
0
SX
---
8
Standard position Y
Get only
−
99,999.9999 to 99,999.9999
0
SY
---
9
Difference in position
Get only
−
99,999.9999 to 99,999.9999
0
DF
Logged data
103
Output
parame-
ter
Reflect
Set / Get 0: Yes, 1: No
0
---
---
120
Set color Set color
Set / Get 0: No edge color specification,
1: Edge color specification
0
---
---
121
Edge color red
Set / Get 0 to 255
255
---
---
122
Edge color green
Set / Get 0 to 255
255
---
---
123
Edge color blue
Set / Get 0 to 255
255
---
---
132
Mea-
sure-
ment
condi-
tions
Edge level
Set / Get 0 to 100
50
---
---
133
Noise level
Set / Get 0 to 442
5
---
---
External
refer-
ence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......