Adjusting the Images That Were Taken
FQ2-S/CH User’s Manual
117
3
Ta
ki
ng Ima
ges
• Measurement Data That Can Be Logged
The values below can be logged as measurement data.
Parameter
Setting
Description
Judgement
-2: No judgement (not measured)
0: Judgement is OK
-1: Judgement is NG
-15: Out of range error
This is the judgement result.
Scroll X
-99,999.9999 to 99,999.9999
This is the amount of position compensation for the X
coordinate.
Scroll Y
-99,999.9999 to 99,999.9999
This is the amount of position compensation for the Y
coordinate.
Edge 0 position X -99,999.9999 to 99,999.9999
This is the X coordinate of the measured edge 0 position.
Edge 0 position Y -99,999.9999 to 99,999.9999
This is the Y coordinate of the measured edge 0 position.
Edge 1 position X -99,999.9999 to 99,999.9999
This is the X coordinate of the measured edge 1 position.
Edge 1 position Y -99,999.9999 to 99,999.9999
This is the Y coordinate of the measured edge 1 position.