Menu Tables
474
FQ2-S/CH User’s Manual
Run Mode
Menu command
Description
Setting range
Data
S
e
lect di
sp
lay Graphic
Displays the input image.
---
---
Gr Details
Displays the inspection item individual
judgement results and measurement val-
ues.
---
Statistical data
Displays the total number of measure-
ments and the total number of NG overall
judgements and the NG ratio from when
the power supply was turned ON.
---
All results/Region
Displays the inspection item individual
judgement results for all inspection items.
---
Trend Monitor
Displays the individual judgement results
saved in the Sensor in a trend monitor.
---
Histogram
Displays the individual judgement results
saved in the Sensor in a histogram.
---
---
---
Model region
(Search, Shape Search
IIl, Search, Shape
Search II, and Sensi-
tive Search only in
[Adjustment mode in
Run] to [ON])
Changes to Setup Mode to adjust the
model region set for each inspection item.
---
---
Insp. region
(Only in [Adjust-
ment mode in Run]
to [ON])
Changes to Setup Mode to adjust the
inspection region set for each inspection
item.
---
Select display image
(Area and Labeling
only)
Changes the display method of the
extracted color.
・
For Area and Labeling
・
Measurement image (Default)
・
Color extraction image
・
Binary image after extraction
・
For Area and Labeling
・
Measurement image (Default)
・
ImageMeas. Img.+Targ. Mdl.
・
Edge Image
・
Edge Image+Targ. Mdl.
---
Adjust judgement
(Except for statistical
data)
Adjusts judgement parameters without
stopping measurements.
---
---
Auto display (trend
monitor and histo-
gram only)
Automatically sets the display range
according to the measurement results.
OFF
ON (Default)
Touch
Finder
data
Display range (trend
monitor and histo-
gram only)
Changes the display range of measure-
ment values.
Measurement value:
−
999,999,999 to
999,999,999
(Defaults: Lower limit: 0
Upper limit: 100)
class: 5 to 100 (Default: 10)
(Histograms only)
Number of data
(trend monitor only)
Changes the number of displayed mea-
surement values.
200
400
1000 (Default: 200)
Number of data (his-
togram only)
Changes the number of displayed mea-
surement values (i.e., the vertical display
range of the histogram).
5 to 1,000
Clear results
(graphic or g
details list)
Clears the measurement results of the
inspection items.
---
---
Delete stats (total
data)
Clears the Statistical data.
---
---
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......