Inspecting with the Area Inspection Item
FQ2-S/CH User’s Manual
307
4
Setting Up Inspect
ions
• Sensors with Monochrome Cameras (or for a Color Gray Filter)
1
Press [ ]
−
[Set color] on the right of the display.
2
Press [ ]
−
[Binary level].
3
Specify the range of brightness to detect,
and then press [OK].
Specify the range of brightness to convert to a bina-
ry image. Measurement is performed after the im-
age taken by the camera in 256-color grayscale is
converted to a binary image. Then, white pixels are
measured.
4
Press [OK].
5
Press [TEACH].
6
Press [Back] to end teaching.
Making the Extraction Results Easier to Check
• You can invert the black/white extraction results.
Press [ ]
−
[Reverse] and select [Yes].
• You can select whether to display a binary image.
Press [ ]
−
[Binary image display] and select [OFF] or [ON].
Note
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......