Menu Tables
FQ2-S/CH User’s Manual
465
Appe
ndi
ce
s
9
Test Tab Page
Menu command
Description
Setting range
Data
Continuous test
Used to check the individual judgment
results for the inspection items and to
adjust the judgment parameters.
---
---
Graphic
Displays the input image.
Gr Details
Displays the inspection item individual
judgment results and measurement val-
ues.
All results/Region
Displays the inspection item individual
judgment results for all inspection items.
Trend Monitor
Displays the individual judgment results
saved in the Sensor in a trend monitor.
Histogram
Displays the individual judgment results
saved in the Sensor in a histogram.
Model region
Same as for the Search item settings.
Scene
---
Insp. region
Scene
Adjust judgement
Adjusts judgment parameters without
stopping measurements.
---
Scene
Result type
Specifies the measurement result type.
Absolute value (Default)
Relative value
Ratio
Co
nti
nuou
s t
est
Display setting
Specifies whether to display individual
inspection results.
Area
,
Labeling
Measurement image
All color image (Default)
Selected color image
Binary image
When the Shape Search lll..
Meas. Img.
Meas. Img.+Model Img.
Edge Image
Edge Img.+ Model Img.
Scene
Auto judgement con-
dition setting
Automatically adjusts the judgment
parameters by using actual workpieces
which are considered as good or faulty
products.
OK Teach
NG Teach
Method
Selects the expression to use to auto-
matically adjust the judgment parame-
ters.
Threshold (minimum)
Threshold (average) (Default)
Threshold (maximum)
Auto display (trend
monitor and histo-
gram only)
Same as the trend monitor and histogram for [Run] Mode.
---
Display range (trend
monitor and histo-
gram only)
Number of data
(trend monitor only)
Number of data
(histogram only)
Erase display
---
Save data
Saves scene data, Calibration data, and
system data.
---
---
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......