![background image](http://html1.mh-extra.com/html/omron/fq2-s-ch-series/fq2-s-ch-series_user-manual_742878162.webp)
Reading with OCR
160
FQ2-S/CH User’s Manual
Use the following examples as reference for setting of the date parameter.
E.g.1
Measurement is performed on 9/30, and the period setting is: Year: 1, Month: 1, Day: 1.
[Month
→
Day]: A month is added to 9/30, and the result will be 10/30.
A day is added to 10/30, and the result will be 10/31.
[Day
→
Month]: A day is added to 9/30, and the result will be 10/1.
A month is added to 10/1, and the result will be 11/1.
E.g.2
Measurement is performed on 1/31, and the period setting is: Year: 0, Month: 1, Day: 1.
・
[Month
→
Day]: A month is added to 1/31, and the result will be 2/31.
The month end adjustment will be applied since 2/31 does not exist.
The result of the month end adjustment plus 1 will be the verification string.
[Day
→
Month]: A day is added to 1/31, and the result will be 2/1.
The month end adjustment will not be applied since 2/31 exists.
A month is added to 2/1, and the result will be 3/1.
[Day
→
Month]: A day is added to 1/31, and the result will be 2/1.
The month end adjustment will not be applied since 2/31 exists.
A month is added to 2/1, and the result will be 3/1.
Measurement is performed on 10/30, and the period setting is: Year: 0, Month: 1, Day: 1.
[Month
→
Day]: A month is added to 10/30, and the result will be 11/30.
The month end adjustment will not be applied since 11/30 exists.
A day is added to 11/30, and the result will be 12/1.
[Day
→
Month]: A day is added to 10/30, and the result will be 10/31.
A month is added to 10/31, and the result will be 11/31.
The month end adjustment will be applied since 11/31 does not exist.
Note
2/28
3/1
3/3
Month end adjust
Result
Last day of current month
First day of next month
Gap day of next month
11/30
12/1
12/1
Last day of current month
First day of next month
Gap day of next month
Month end adjust
Result
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......