Shortening the Measurement Takt Time
FQ2-S/CH User’s Manual
343
5
Testin
g
a
nd Savin
g Se
ttin
gs
Increasing Image Input Speed
With the partial input function, it is possible to input only images that are in the region that is necessary for
measurements.
The image measurement region becomes smaller and therefore the image input time is shortened.
Consider the offset in the measurement object when you set the range.
The image in the input range will be displayed in the inspection item setting displays and measurement
displays.
• FQ2-S3/S4
[Image]
−
[Camera setup]
1
Press [ ]
−
[Partial input] on the right side of
the display.
2
Press [Y] and set the input range along the Y
axis by setting the Y coordinate of the partial in-
put start point and the Y coordinate of the par-
tial input end point.
3
Press [X] and set the input range along the X
axis by setting the X coordinate of the partial in-
put start point and the X coordinate of the par-
tial input end point.
4
Press [OK].
Partial input Y start line
Partial input Y end line
Y coordinate of the
partial input start point
Y coordinate of the
partial input end point
Partial input X
start line
X coordinate of the
partial input start point
X coordinate of the
partial input end point
Partial input X
end line
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......