Inspecting with the Edge Width Inspection Item
FQ2-S/CH User’s Manual
283
4
Setting Up Inspect
ions
Step 2
Teaching
Teaching means to store the region and the edge width in the region as reference data for the measurement.
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Edge Width]
−
[Settings] Tab Page
The following data is stored as the measurement reference.
1
Press [Teach].
2
Place the object that is to be used as the measurement reference in front of the camera.
3
Move the rectangle to the location to be measured.
4
Press [OK].
5
Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has been completed.
6
Press [Back] to end teaching.
Changing the measurement region: p. 227
Item
Parameter
Description
Reference data
Reference width
The reference edge width is set automatically.
The middle arrow is the
direction for detecting an edge.
Moves the end point
of the measurement
region.
Changes the width
of the measurement
region.
Moves the starting point
of the measurement
region.
Drag to move
the region.