Inspecting with the Shape Search III Inspection Item
238
FQ2-S/CH User’s Manual
Reflect in Total Judgment
You can specify whether to reflect the judgment results of an inspection item in the overall judgment.
The Default is to reflect them.
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Shape Search III]
−
[Details] Tab Page
−
[Output parameter]
Unstable Shape Search III Results
Inclined Measurement Objects
The search area for the model can be expanded by adjusting [Angle range].
The OK or NG Judgment is determined by the correlation to the registered image pattern for the search.
Therefore, there may be an NG judgment result for good workpiece if the correlation is low due to the angle
being slanted.
In this case, to get an OK judgment, increase the Angle range.
[Inspect]
−
[Inspection]
−
[Shape Search III]
−
[Modify]
−
[Details] Tab Page
−
[Model parameter]
1
Set [Rotation] to [Yes].
2
Press [Angle range] and set the following range.
Parameter
Setting
Description
Angle range
Range:
−
180 to 180
Default: Lower:
−
180
Upper: 180
A shape search II is performed within the set angle range.
The larger the angle range, the longer the processing time.
If you change the angle range, perform teaching again.
Important
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......